dc.description.abstract |
In recent decades, energy demand has grown exponentially. Fossil fuels, which today meet the
bulk of global energy demand, can be gradually replaced by renewable energies, thus limiting its
dangerous consequences such as climate change, environmental pollution, depletion of natural
resources, etc. Solar energy can play an important role in the satisfaction of energy demand,
especially in a country heavily sun-ridden.
The current study focuses on the modelling and optimization of Organic Rankine Cycle (ORC)
based on different organic fluids operating in a temperature range below 50-100 °C. The ORCs
are a good choice to produce small-scale energy due to the lower temperature range of 50 to 99 °
C. They are therefore simple and inexpensive. Flat plate (FPC) or evacuated tube solar collectors
(ETC) can also provide the desired energy.
In this work, two system configurations are analyzed. In configuration-I (C-I), the water from the
collector outlet moves to the hot water storage tank (HWST) connected in series, while in
configuration-II (C-II), HWST is not used. Therefore, the hot water from the solar collector outlet
enters directly into the auxiliary heater (which will be lit if necessary, otherwise) and the water
return from the heat exchanger will become the input of the solar collector.
Working fluids suitable for a solar-powered ORC at a temperature of 100 ° C or lower are selected
using predefined criteria such as higher fluid densities, maximum cycle efficiency, safety and
environmental data, a moderate temperature and inexpensive and uncomplicated equipment.
The R125 and R245ca were found to be good fluids due to the minimum collector area for the
desired yield and maximum efficiency, respectively. For the R125, the minimum required collector
area is estimated to be 50 m² for the ETC and 68.14 m² for the FPC. For these areas, the optimized
size of the HWST is estimated at 1350 L.
System configurations are modelled and simulated in TRNSYS for the entire year, from January
1
st to December 31ST , to investigate optimal collector tilt, the smallest collector area for maximum
solar fraction, and solar collector thermal efficiency. monthly solar collector efficiency for both
configurations. The results of the simulation showed that C-II gives a comparatively higher solar
collector thermal efficiency and solar fraction. For both collectors, the maximum seasonal solar
fraction is obtained at an inclination of approximately 14°.Papoutsis et al. presented similar trend
ix
for a solar adsorption cooler. Their results showed that the maximum of SF is obtained at a tilt of
14° for Athens, Greece.
C-II for ETC gives a thermal efficiency of solar collector comparatively higher than that of C-I
and one observes the same trend for FPC. In addition, the thermal efficiency of the ETC at 50 m²
is higher than that of the FPC at an area of 68.14 m². |
en_US |